Menu
    Home › Resources › Alloy data › 5052 Aluminium Alloy — Technical Data

5052 Aluminium Alloy — Technical Data

A magnesium-containing aluminium alloy referenced for hydraulic tube applications. Product form and cold-work condition must accompany any strength comparison.

Selected reference facts; incomplete alloy coverage. Keep typical values, source minima and composition limits distinct. Reference records are not certificates or design allowables.

Download Technical Data Sheet

Grade, forms and temper conditions

5000 series · Tube and pipe

Reviewed temper examples: O, H32, H34. These do not establish every possible alloy-form-temper supply combination.

Physical properties

Numerical physical properties are not verified for this record and remain withheld.

Mechanical reference properties — MPa
TemperProduct formThickness / specimen conditionTensile MPaYield MPaBasisSource ID
OTube and pipeTensile specimen elongation basis 4D; material thickness unspecified19590typicalkaiser5052
H32Tube and pipeTensile specimen elongation basis 4D; material thickness unspecified230195typicalkaiser5052

O / Tube and pipe: Supplier reference; thickness of tensile specimen section; not a certificate or design allowable; checked 2026-10-14.

H32 / Tube and pipe: Supplier reference; thickness of tensile specimen section; not a certificate or design allowable; checked 2026-10-14.

Chemical composition

Composition coverage remains pending source review.

Fabrication and material selection

The referenced document reports typical tube properties. These are not sheet specification limits. Density is withheld because the source labels its unit inconsistently.

Applications and product forms

Hydraulic tubing

Standards and acceptance

Identify the governing product specification by the actual form and manufacturing route. A grade designation alone does not establish compliance or equivalence. Confirm the edition, required condition, inspection and dimensional limits through the supplier and an authorized specification.

Product-specific standard scopes · Compare material conditions · Engineering calculators

Withheld or conflicting values

  • Density unit is inconsistent in the source; withheld pending independent verification.
  • Composition table labelled nominal; not imported as guaranteed chemical limits.

Technical questions

Are typical values delivery limits?

No. A typical reference value describes the source condition; it is not a guaranteed minimum for a delivered lot.

Which temper and thickness should I compare?

Compare the same material form, temper, thickness/test condition, unit and value basis. Different conditions cannot be silently treated as interchangeable.

Technical sources and verification

Selected reference facts checked 14 October 2026. Source values apply to their stated material condition and are not certification of supplied stock.