A manganese-family sheet alloy with an H14 reference condition. Rolled-sheet properties retain their thickness range.
Selected indicative supplier facts; specification verification remains required. Keep typical values, source minima and composition limits distinct. Reference records are not certificates or design allowables.
Grade, forms and temper conditions
3000 series · Sheet
Reviewed temper examples: H14. These do not establish every possible alloy-form-temper supply combination.
| Property | Value | Unit | Temper / form | Condition | Basis / verification | Source ID |
|---|---|---|---|---|---|---|
| Density | 2730 | kg/m³ | Not specified / Sheet | Temperature not specified; indicative supplier reference | typical / single-source | aalco3103 |
| Temper | Product form | Thickness / specimen condition | Tensile MPa | Yield MPa | Basis | Source ID |
|---|---|---|---|---|---|---|
| H14 | Sheet | 0.2–6.0 mm; supplier cites BS EN 485-2:2008 | 140–180 | 120 | indicative-range | aalco3103 |
H14 / Sheet: Supplier indicative reference; not guaranteed specification limits; checked 2026-10-14.
Chemical composition
Composition coverage remains pending source review.
Fabrication and material selection
The electrical field uses a conductivity unit under a resistivity heading, so it is withheld. No exact equivalence to other manganese alloys is inferred.
Applications and product forms
Confirm the end-use requirements against the supplied material and governing specification.
Standards and acceptance
Identify the governing product specification by the actual form and manufacturing route. A grade designation alone does not establish compliance or equivalence. Confirm the edition, required condition, inspection and dimensional limits through the supplier and an authorized specification.
Product-specific standard scopes · Compare material conditions · Engineering calculators
Technical questions
Are typical values delivery limits?
No. A typical reference value describes the source condition; it is not a guaranteed minimum for a delivered lot.
Which temper and thickness should I compare?
Compare the same material form, temper, thickness/test condition, unit and value basis. Different conditions cannot be silently treated as interchangeable.
Technical sources and verification
Selected reference facts checked 14 October 2026. Source values apply to their stated material condition and are not certification of supplied stock.
- Aalco 3103 H14 sheet reference — Public indicative data; historical EN editions cited