Epoxy powder coating
Applied by electrostatic spray or fluidised bed and cured. Hard, adherent and conformal over bends, with high dielectric strength. Sharp edges coat thinner, so edge radii must be specified.
An insulated high-voltage aluminium busbar is a rigid aluminium conductor, formed to shape and covered with an insulating layer except at its contact faces. It carries high current in EV battery packs, inverters, energy storage and switchgear at about half the weight of copper for the same resistance. Metline supplies conductor bar and formed, insulated busbars to drawing, with certified material, worldwide.

A busbar is a solid conductor that distributes current between components. In compact high-voltage systems, such as an electric vehicle pack running at 400 or 800 V, bare bars would need large air gaps to prevent flashover. Insulating the bar lets designers route conductors closely and safely, protects against accidental contact and keeps debris from bridging phases.
An insulated busbar is a system with three parts that must be specified together: the conductor (alloy, temper, cross-section and shape), the insulation (material, thickness, temperature class and dielectric rating), and the connections (exposed contact faces, plating, holes, welds or fasteners). A bar that fits the space is not yet a busbar; it also needs a thermal and electrical review for the current, voltage and environment it will see.
Aluminium is increasingly chosen for these parts because weight and cost matter in vehicles and large installations. For the same DC resistance an aluminium bar needs about 1.6 times the cross-section of copper, yet weighs only about half as much, and it costs considerably less per ampere carried. The penalty is a larger section and more careful joint design, because aluminium forms a hard oxide and creeps under sustained bolt load.
The choice is a trade-off between conductivity and strength. Pure grades conduct best; 6101 adds strength for bars that must stay rigid over long spans or carry mechanical load. Values are typical; guaranteed minimum conductivity is set by the order standard and reported on the certificate.
| Alloy / temper | Electrical conductivity (% IACS) | Resistivity at 20 °C (µΩ·cm) | Typical tensile strength | Notes |
|---|---|---|---|---|
| 1350 (EC grade) | about 61 – 62 | about 2.8 | about 80 – 190 MPa depending on temper | Electrical conductor grade, Al ≥ 99.50 % |
| 1060 | about 61 – 62 | about 2.8 | about 70 – 130 MPa depending on temper | Widely used for formed EV busbars |
| 1050A | about 60 – 61 | about 2.85 | about 65 – 150 MPa depending on temper | European equivalent, good formability |
| 6101-T6 / T61 / T63 | about 55 – 57 | about 3.0 – 3.1 | 200 – 220 MPa (T6) | Higher strength for rigid or long bars |
| Copper C11000 (reference) | 100 | 1.72 | 220 – 300 MPa | Smaller section, about 3.3 × the density |
| Comparison at equal resistance | Aluminium (1350 / 1060) | Copper |
|---|---|---|
| Relative cross-section | about 1.6 | 1.0 |
| Relative weight | about 0.5 | 1.0 |
| Density | 2.70 g/cm³ | 8.89 g/cm³ |
| Thermal expansion | about 23 µm/m·°C | about 17 µm/m·°C |
Applied by electrostatic spray or fluidised bed and cured. Hard, adherent and conformal over bends, with high dielectric strength. Sharp edges coat thinner, so edge radii must be specified.
Thermoplastic coating applied by fluidised bed. Tough and flexible, resists cracking under vibration and thermal cycling, and tolerates later bending better than epoxy.
Polyolefin or other sleeves shrunk over straight and gently bent bars. Low tooling cost and easy to change; less suited to complex 3D shapes and tight bends.
PET, PI or similar films laminated around flat conductors, often in stacked laminated busbars that cut inductance in inverters.
Silicone, TPE or other polymers moulded or extruded onto the bar. Thick, robust insulation for high voltage and harsh environments.
Insulation only where clearance is tight, with bare sections elsewhere. Saves cost but needs careful creepage and clearance design.
Select insulation on four properties: dielectric withstand at the system voltage with margin, continuous temperature class above the bar's hot-spot temperature, flame rating (often UL 94 V-0 for battery packs), and mechanical durability against vibration, abrasion and thermal cycling. Ask for the tracking index (CTI) where the bar sits in a humid or contaminated environment.
| Design check | What to confirm | Reference |
|---|---|---|
| Current rating | Temperature rise of the bar at continuous and peak current, including joints | IEC 61439-1 temperature-rise limits; thermal simulation or test |
| Short-circuit withstand | Mechanical force and thermal rise during fault current | System fault study |
| Creepage and clearance | Distances at exposed terminals and where insulation ends | IEC 60664-1; ISO 6469-3 for vehicles |
| Dielectric withstand | AC or DC withstand voltage of the insulation, and insulation resistance | Product or customer specification |
| Partial discharge | Inception voltage for 800 V-class and higher systems | Customer specification |
| Thermal cycling and vibration | Insulation adhesion and joint stability over life | Vehicle or application test plan |
Aluminium needs particular attention at joints. Clean and abrade the contact surface, use a contact compound or plating, and keep bolt preload steady with spring or Belleville washers so creep does not loosen the joint. Contact faces are often tin- or nickel-plated, or a copper–aluminium bimetallic insert is used where the bar meets a copper terminal. In battery packs, aluminium busbars are frequently laser or ultrasonically welded to cell tabs instead of bolted.
For straight conductor bar without insulation, see our aluminium busbar page.
Weight and cost. For the same resistance an aluminium bar needs about 1.6 times the cross-section of copper but weighs about half as much and costs less. Where space allows the larger section, aluminium reduces pack mass and material cost.
1350 or 1060 for maximum conductivity (about 61 – 62 % IACS) and easy forming. 6101 in T6 or T61 is used where the bar must be stiffer or stronger, accepting conductivity of about 55 – 57 % IACS.
Epoxy powder gives high dielectric strength and a hard finish and is the common choice for rigid bars. Polyamide (PA11/PA12) is tougher and more flexible, so it resists cracking from vibration, thermal cycling or later bending. The right choice depends on voltage, temperature and mechanical duty.
With plated contact faces (tin or nickel), a contact compound, and bolted joints that use spring washers to hold preload. For permanent joints, bimetallic copper–aluminium inserts or friction-welded transitions avoid galvanic corrosion at the interface.
Typically dimensional inspection, insulation thickness, adhesion, dielectric withstand (hipot) and insulation resistance, with partial discharge testing for 800 V-class systems where specified. Conductor conductivity is reported on the material certificate.
Yes. We supply certified conductor bar and strip, and formed and insulated busbars made to your drawing, to customers worldwide.
Send the drawing, voltage, current and insulation requirement. We will reply with conductor, insulation and test options and a delivered price.