Reel-Fed Insulated Aluminium Busbar for EV High-Voltage Systems

Insulated aluminium flat conductor is a solid aluminium alloy bar with continuous insulation, supplied on reels so that busbar makers can straighten, cut, strip, bend and terminate high-voltage connections in-house. It replaces copper busbars and heavy cables in battery packs, junction boxes and the charging path of electric vehicles at roughly half the weight for the same resistance. This guide covers conductor alloys, insulation options, processing and validation.

Insulated aluminium flat conductor for electric vehicle high-voltage busbars
Conductor
6101 aluminium alloy
Tempers
T61, T63, T64, T65
Cross-section
About 120 – 200 mm²
Insulation
PA12, PVC, PE or fire-barrier composite
Overview

What reel-fed insulated aluminium busbar is

A high-voltage battery electric vehicle moves hundreds of amps between the battery pack, the battery junction or disconnect unit (BJB / BDU), the inverter and the charging inlet. Rigid busbars carry that current along fixed routes; flexible cables are used where parts move.

Traditionally the rigid links were copper bars, stamped and then insulated one by one with heat-shrink tube or powder coating. A reel-fed insulated aluminium conductor reverses the sequence: the aluminium flat bar is insulated continuously first and supplied on a reel, and the busbar maker cuts it to length, strips the insulation only where the terminals go, and bends it into the final 3D shape. That removes a separate insulation step for every part and suits automated high-volume lines.

Metline supplies the aluminium conductor material. The customer, or the customer's busbar supplier, carries out forming, termination and assembly, so the material has to be specified around that downstream process as well as around electrical performance.

Weight and resistance

Why aluminium: equal resistance at about half the weight

Aluminium conducts about 61 % as well as copper by volume, so a conductor needs a larger cross-section to reach the same resistance: about 1.64 times larger when comparing electrical-grade aluminium with annealed copper. Because aluminium is less than a third as dense, the larger aluminium bar still weighs about half as much. The table works this through for common copper sizes, using resistivity ratio and density only.

Copper section (mm²)Aluminium section for equal resistance (mm²)Copper mass (kg/m)Aluminium mass (kg/m)
50820.440.22
701150.620.31
951560.840.42
1201971.070.53
1502461.330.66

Calculated with 2.82 µΩ·cm for EC-grade aluminium, 1.72 µΩ·cm for annealed copper, and densities of 2.70 and 8.89 g/cm³. 6101 alloys have slightly lower conductivity than EC-grade aluminium, so add a margin and confirm with temperature-rise tests.

The penalty is space: the aluminium bar is wider or thicker. In practice designers often use the extra width as a cooling surface, because a flat bar sheds heat well. Where packaging space is tight, copper or copper-clad aluminium may still be the right choice for a short link.

Conductor

Conductor alloy and temper: 6101

Most insulated aluminium busbars use 6101, a heat-treatable Al-Mg-Si alloy developed for electrical conductors. It combines conductivity of roughly 55 – 60 % IACS with much higher strength than pure EC-grade aluminium, which matters when a bar has to hold its bent shape, carry bolt loads and survive vibration. ASTM B317 covers 6101 extruded bus conductor in several tempers.

TemperTreatmentBalance of propertiesTypical use
6101-T61Solution treated and over-aged for conductivityHigh conductivity, moderate strength, good formabilityBusbars that are bent in several planes
6101-T63Aged for higher strengthHigher strength, slightly lower conductivityLong unsupported spans, bolt-loaded terminals
6101-T64Aged for maximum conductivityHighest conductivity and best bendability, lowest strengthCurrent-dense links with tight bends
6101-T65Intermediate ageingBalanced strength and conductivityGeneral high-voltage routing
1350 / 1060 (alternative)Non-heat-treatable pure gradesAbout 61 – 62 % IACS, low strengthSupported routes where bend retention is less critical

Minimum conductivity and strength for each temper are set by the applicable standard and the project specification and are reported on the mill certificate.

Insulation

Insulation options: polymer or fire-resistant composite

Polymer insulated

A continuous extruded jacket of PA12, PVC, PE or another polymer, typically from about 0.5 mm thick, chosen for dielectric strength, temperature class, abrasion resistance and how cleanly it strips. Suited to standard high-voltage routing inside the pack and junction box.

Fire-resistant thermal-barrier composite

The aluminium core is wrapped with a fire or thermal barrier layer (for example mica-based or ceramifying materials) under an outer polymer jacket. Intended for bars that run close to cells or modules where flame or high heat from a thermal event must not cause a short circuit.

Alternatives

Heat-shrink tubing, powder epoxy coating or dip coating applied after forming. These suit low volumes or complex 3D parts but add a separate process for each part.

Engineering situationInsulation to evaluate first
Standard high-voltage routing where insulation, current and weight are the prioritiesPolymer insulated
Dense BJB / BDU interfaces with many bends, strips and terminalsPolymer insulated
Routing next to cells, modules or another defined heat sourceFire-resistant thermal-barrier composite
Project requires a fire-resistance or thermal-barrier test on the busbarFire-resistant thermal-barrier composite
One route crosses zones with different thermal riskDesign to the highest-risk zone along the route
On-vehicle charging inlet to battery pathDecide from charge current, terminal temperature rise and surrounding heat

Flame retardancy, fire resistance and thermal insulation are different properties. A material rating for flammability (for example UL 94) does not show that the complete bar keeps its insulation during a flame or thermal-runaway exposure; that has to be tested on a formed sample with the project's temperature, duration and measuring point.

Downstream processing

From reel to finished busbar

A typical line runs: reel feeding, straightening, cutting to length, stripping, bending or forming, and terminal preparation. Each step puts its own demands on the material.

  1. Feeding and straighteningReel size, winding direction, straightness and twist decide whether the bar feeds smoothly. Define reel dimensions, weight per reel and winding pattern to suit your decoiler.
  2. CuttingShear or saw cutting must leave the insulation intact up to the cut and the conductor free of burrs that could damage the jacket.
  3. StrippingInsulation is removed at terminals by laser ablation or mechanical stripping. Specify strip position, length, a clean boundary and the allowed residue on the aluminium.
  4. BendingFlatwise and edgewise bends stress both conductor and jacket. Bend capability depends on temper, width-to-thickness ratio, edge radius, bend radius and insulation type; qualify it on real samples.
  5. Terminal preparationPunching or drilling holes, flattening, plating contact areas, welding or fitting terminals. For the composite type, define how the barrier layers end at the terminal.
Connections

Making reliable aluminium busbar joints

  • Oxide film: aluminium forms a thin oxide immediately. Contact areas are cleaned and often tin- or nickel-plated so that the contact resistance stays low and stable.
  • Creep at bolted joints: aluminium relaxes under sustained bolt load more than copper. Use larger washers or conical spring washers, controlled torque and a joint design validated by thermal cycling.
  • Aluminium to copper: direct contact in a damp environment causes galvanic corrosion. Use plated interfaces, bimetallic transition pieces or welded Al-Cu joints, and seal the joint where moisture can reach it.
  • Welded connections: laser and ultrasonic welding are widely used to join aluminium bars to cell tabs and terminals; weld parameters must be qualified for the specific alloy and temper.
  • Clearance and creepage: terminal areas must keep the insulation distances required by the system voltage and pollution degree, following insulation-coordination rules such as IEC 60664-1.
Testing

What to verify after forming

CheckWhat to look forApplies to
Bend integrityNo cracking, whitening, wrinkling or thinning of the insulation at bendsAll types
Strip and terminal conditionClean strip boundary, no residue on contact faces, no conductor nicksAll types
Dielectric withstand and insulation resistancePass the voltage and resistance levels set by the OEM specificationAll types
Formed dimensionsCritical interfaces and hole positions within drawing toleranceAll types
Resistance and temperature riseJoint resistance and temperature rise under rated continuous and peak currentAll types
Layer continuityNo delamination; barrier layer continuous through bendsComposite type
Thermal or flame exposureInsulation maintained for the required time on a formed sampleComposite type

New projects normally start with samples built to the agreed conductor, insulation and reel configuration, which the customer runs through its own equipment and tests. Once approved, that configuration becomes the supply baseline, with reel or batch traceability, inspection records and an agreed change-control process for any material or process change.

Selection

When reel-fed insulated aluminium makes sense

Good fit

  • Rigid, flat or bent high-voltage routes that repeat from vehicle to vehicle
  • In-house capability for feeding, stripping, bending and terminal processing
  • Stable volume of similar busbar parts
  • Weight reduction is a project target

Consider another form

  • Connections that flex or move in service: use a high-voltage cable or flexible busbar
  • You buy only finished, terminated 3D busbar assemblies
  • No capability to strip, terminate or join aluminium conductors
  • Small quantities of complex parts, or no space for the larger aluminium section
Sources

References and standards

  1. ASTM B317/B317M – Aluminum-Alloy Extruded Bar, Rod, Tube, Pipe, Structural Profiles and Profiles for Electrical Purposes (Bus Conductor)
  2. ISO 6469-3 – Electrically propelled road vehicles: safety specifications, electrical safety
  3. IEC 60664-1 – Insulation coordination for equipment within low-voltage supply systems
  4. UL 94 – Standard for Tests for Flammability of Plastic Materials for Parts in Devices and Appliances
  5. ISO 19642 – Road vehicles: automotive cables (including high-voltage cables)
FAQ

Insulated aluminium (aluminum) busbar: FAQ

How is the minimum bend radius of an insulated aluminium busbar decided?

There is no single value. It depends on the temper, the width-to-thickness ratio, whether the bend is flatwise or edgewise, the angle and the insulation material, and it should be confirmed by bending real samples on your equipment.

Does the fire-resistant composite type keep its protection after bending?

It should, but that must be proved on formed samples: check that the barrier layer stays continuous and undamaged through the bends and then run the thermal or flame test on the formed part.

How is the insulation handled at the terminals?

It is removed locally by laser or mechanical stripping. The strip position, length, boundary quality and allowable residue are defined on the drawing, and contact faces are usually plated.

Why use 6101 rather than pure aluminium?

6101 keeps conductivity close to pure aluminium while giving much higher strength, so bent busbars hold their shape, resist vibration and carry bolt loads better.

Is an aluminium busbar really lighter if it has to be bigger?

Yes. For equal resistance the aluminium section is about 1.6 times larger, but because aluminium is about a third of the density of copper the bar weighs roughly half as much.

What documents come with the material?

Mill test certificates with chemistry and properties, dimensional inspection records, agreed performance test results and reel or batch traceability. Additional automotive project documents are agreed at project start.

Need insulated aluminium conductor on reels?

Send the application, drawing or target cross-section, insulation requirement and volume. We will review it and reply with a supply proposal.